Your engineering partner in industrial automation
[email protected]+90 546 425 20 69
Beijer X2 base 5 v2 (Basic Performance)
Beijer

Beijer X2 base 5 v2 (Basic Performance)

Next-generation X2 Base: economical, fully featured operator panels The X2 Base operator panel family was updated with the 2nd-generation X2 Base panels, offering higher performance, more di

Application-specific product selectionEngineering and technical consulting
Request a product quotationTalk to our team · +90 546 425 20 69

Next-generation X2 Base: economical, fully featured operator panels

The X2 Base operator panel family was updated with the 2nd-generation X2 Base panels, offering higher performance, more display sizes and additional features. X2 base v2 provides cost-effective industrial operator panels with high-resolution touchscreens and a modern design. Combining IP65 corrosion-resistant plastic housings with iX developer functionality, the panels offer an advanced HMI solution for small and medium-sized applications.

X2 base v2 panels are offered in standard 5, 7 and 10-inch sizes, with 7, 10 and 15-inch sizes for high-performance models.

The source catalog listed a planned launch for the high-performance versions in the second half of 2021. Contact our team for current availability.

 

Corrosion-resistant Plastic Housing

Corrosion-resistant plastic housing with an IP65, NEMA 4X/12 and UL Type 4X/12 front, protecting against rain, snow, high-pressure water, dirt and dust.

Energy-efficient ARM9 Processors

Energy-efficient ARM9 processors provide performance for small and medium-sized applications.

Widescreen Format

X2 panels offer a widescreen format designed to replace the traditional 4:3 aspect ratio.

 

 

  • 800 × 480 pixel (5:3)
  • TFT-LCD touch screen
  • 1 × Ethernet, 4 × serial, 1 × USB as standard
  • Operating temperature -10° to +50° C
  • CE, FCC, UL approvals


Facts

General description
Part number
630005110
Life cycle status
Active
Warranty
2 year
Certifications
General
CE, FCC, UL 61010-2-201
Safety
UL 61010-1, UL 61010-2-201, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201
Mechanical
Mechanical size
173 x 109 x 37mm
Panel Mount
1million finger touch operations
Touch type
Resistive
Cut-out size
161 x 93mm
Weight
0.32 kg
Housing material
Plastic (PC+ABS), Gray
Buzzer
No
LED
No
Power
Input voltage
24 V DC (18 to 32 VDC) CE: The power supply has to be conform with the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supply has to be conform with the requirements for class II power supplies.
Power consumption (max)
4.8 W
Input fuse
Internal DC fuse
Hardware platform
X2 base v2
CPU
ARM Cortex A8 600MHz
RAM
512 MB
FLASH
2 GB
Display
Size diagonal
5.0" diagonal
Resolution
800 × 480 pixel (5:3)
Backlight
LED Backlight
Backlight life time
20000 hours
Backlight brightness
250 cd/m²
Backlight dimming
Industrial Dimming
Display type
TFT-LCD with LED backlight
Digtal IO
Digital output
No
Serial communication
Number of serial ports
1port9pinDsub, 1port3pinScrew
Serial port 1
RS 232 (RTS/CTS)
Serial port 2
RS422/485
Serial port 3
RS 485
Serial port 6
RS 485
Ethernet communication
Number of Ethernet ports
1
Ethernet port 1
1x10/100 Base-T (shielded RJ45)
Expansion interface
Expansion port
No
SD card
No
USB
1
Environmental
Operating temperature
-10°C to +50°C
Storage temperature
-20°C to +60°C
Shock
15g, half-sine, 11ms according to IEC60068-2-27
Vibration
1g, according to IEC 60068-2-6, Test Fc
Sealing front
IP65, NEMA 4X/ 12 and UL 50E Type 4X/ 12
Sealing back
IP20
Humidity
5% – 85% non-condensed
TECHNICAL RESOURCES

The information you need. Within reach.

Check the current manufacturer revision and the conditions applicable to your application.

View documentation (59)
Best Practice Database on SD card or flash memory — ENHow to download Free software packages from SmartStore — ENiX - SMTP - Using Gmail servers using App password — ENiX Developer SP7 - 2.47.473 Release information (iX240SP7 LastMinuteNotes iX PIEN341L) — ENiX Developer SP7 - 2.47.473 Release information (iX240SP7 ReleaseNotes iX PIEN340Q) — ENQuick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411 — ENSD-card Recovery without SD-card (X2 base v2 basic) — ENProgram example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3. — ENProgram example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3. — ENProgram example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3. — ENQuick start guide - Connect X2 HMI with Nexto PLC, SUEN00414 — ENQuick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series, SUEN00402 — ENQuick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406 — ENQuick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405 — ENQuick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403 — ENBattery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs — ENMTBF Summary X2 base v2 — ENX2 export control and dual use — ENX2 Letter of Volatility — ENGuidelines for TxA and TxB migration to X2 — ENGuidelines for TxA and TxB migration to X2 — .pptxEnvironmental report X2 base v2 — ENCE Manufacturer declaration X2 base v2 — ENCE Report X2 base 5 v2 — ENDoC battery X2 base (V2) — ENDoC ECCN for X2 series HMI — ENEnvironmental Impact Report X2 pro, X2 marine, X2 control, X2 motion — ENFCC Report X2 base 5 v2 — ENManufacturer declaration: X2 base v2 UKCA Declaration of Conformity — ENRoHS and REACH Declaration of Conformity — ENSDoC Green Passport — EN3D drawing X2 base 5 v2 — EN3D drawing X2 base 5 v2 — .stepCable CAB113: Cable for ModBus RS485 between X2 panel and BFI — ENInstallation manual X2 base 5 v2, MAEN328 — ENiX Developer Reference Manual, MAEN355 rev. B (current version) — ENX2 base / pro / extreme / marine / control - Configuration and Image manual , MAEN352 rev B — ENX2 base V2 Serial interface mapping — ENRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — ENRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — .exeRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — .zipSqlProxy - Connects iX Panels transparently to SQL Server (161202C) — ENSqlProxy - Connects iX Panels transparently to SQL Server (190115) — ENSqlProxy - Connects iX Panels transparently to SQL Server (191016C) — .zipSqlProxy - Connects iX Panels transparently to SQL Server (170330) — ENX2 brochure (English), BREN631 — ENX2 brochure (Spanish)​ — ESX2 brochure 2019 (French) — FRX2 series (German) — DEX2 base v2 (HP) 1.0.2 b280 (iXCustomSplash) — .cfgX2 base v2 (HP) 1.0.2 b280 (LastMinuteNotes B280) — ENX2 base v2 (HP) 1.0.2 b280 (ReleaseNotes B280) — ENX2 base v2 (HP) 1.0.2 b280 — .exeX2 base V2 1.0 BASIC b261 image (LastMinuteNotes B261) — ENX2 base V2 1.0 BASIC b261 image (ReleaseNotes B261) — ENX2 base V2 1.0 BASIC b261 image — .exeX2 base V2 1.1 (Current version) (LastMinuteNotes B1015) — ENX2 base V2 1.1 (Current version) (ReleaseNotes B1015) — ENX2 base V2 1.1 (Current version) — .exe
EXPLORE THE PORTFOLIO

Related products

WhatsApp
GET IN TOUCH

Let us call you.

Leave your number and let’s discuss what you need.

Your privacy choices

We use technologies needed to operate the website securely. Analytics and advertising tracking are disabled by default.

No analytics service is currently configured.