Your engineering partner in industrial automation
[email protected]+90 546 425 20 69
Beijer X2 base 15 v2 HP (High Performance)
Beijer

Beijer X2 base 15 v2 HP (High Performance)

Next-generation X2 Base: economical, fully featured operator panels The X2 Base operator panel family was updated with the 2nd-generation X2 Base panels, offering higher performance, more di

Application-specific product selectionEngineering and technical consulting
Request a product quotationTalk to our team · +90 546 425 20 69

Next-generation X2 Base: economical, fully featured operator panels

The X2 Base operator panel family was updated with the 2nd-generation X2 Base panels, offering higher performance, more display sizes and additional features. X2 base v2 provides cost-effective industrial operator panels with high-resolution touchscreens and a modern design. Combining IP65 corrosion-resistant plastic housings with iX developer functionality, the panels offer an advanced HMI solution for small and medium-sized applications.

X2 base v2 panels are offered in standard 5, 7 and 10-inch sizes, with 7, 10 and 15-inch sizes for high-performance models.

The source catalog listed a planned launch for the high-performance versions in the second half of 2021. Contact our team for current availability.

 

Corrosion-resistant Plastic Housing

Corrosion-resistant plastic housing with an IP65, NEMA 4X/12 and UL Type 4X/12 front, protecting against rain, snow, high-pressure water, dirt and dust.

Energy-efficient ARM9 Processors

Energy-efficient ARM9 processors provide performance for small and medium-sized applications.

Widescreen Format

X2 panels offer a widescreen format designed to replace the traditional 4:3 aspect ratio.

 

 

  • 1366 × 768 pixel (16:9)
  • TFT-LCD touch screen
  • 2 × Ethernet, 6 × serial, 2 × USB as standard
  • Operating temperature -10° to +50° C
  • CE, FCC, UL approvals


Facts

General description
Part number

630009810

Life cycle status Active
Warranty

2 year

Certifications
General CE, FCC, UL 61010-2-201
Safety UL 61010-1, UL 61010-2-201, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201
Mechanical
Mechanical size

409 x 270 x 43mm

Panel Mount

1million finger touch operations

Touch type Resistive
Cut-out size 393 x 254mm
Weight

2.46 kg

Housing material

Plastic (PC+ABS), Gray

Buzzer

No

LED

No

Power
Input voltage

24 V DC (18 to 32 VDC) CE: The power supply has to be conform with the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supply has to be conform with the requirements for class II power supplies.

Power consumption (max) 17.8 W
Input fuse

Internal DC fuse

Hardware platform

X2 base v2

CPU

ARM Cortex A8 1000MHz

RAM

512 MB

FLASH 2 GB
Display
Size diagonal 15.6" diagonal
Resolution 1366 × 768 pixel (16:9)
Backlight

LED Backlight

Backlight life time 50000 hours
Backlight brightness 300 cd/m²
Backlight dimming

Industrial Dimming

Display type TFT-LCD with LED backlight
Digtal IO
Digital output

No

Serial communication
Number of serial ports

2port9pinDsub,

1port3pinScrew

Serial port 1 RS 232 (RTS/CTS)
Serial port 2 RS422/485
Serial port 3 RS 485
Serial port 4 RS 232
Serial port 5 RS422/485
Serial port 6 RS 485
Ethernet communication
Number of Ethernet ports

2

Ethernet port 1 1x10/100 Base-T (shielded RJ45)
Ethernet port 2 1x10/100 Base-T (shielded RJ45)
Expansion interface
Expansion port

No

SD card

Yes

USB

2

Environmental
Operating temperature

-10°C to +50°C

Storage temperature

-20°C to +60°C

Shock

15g, half-sine, 11ms according to IEC60068-2-27

Vibration 1g, according to IEC 60068-2-6, Test Fc
Sealing front IP65, NEMA 4X/ 12 and UL 50E Type 4X/ 12
Sealing back

IP20

Humidity

5% – 85% non-condensed

TECHNICAL RESOURCES

The information you need. Within reach.

Check the current manufacturer revision and the conditions applicable to your application.

View documentation (56)
iX Developer SP7 - 2.47.473 Release information (LastMinuteNotes iX PIEN341L) — ENiX Developer SP7 - 2.47.473 Release information (ReleaseNotes iX PIEN340Q) — ENBest Practice Database on SD card or flash memory — ENHow to download Free software packages from SmartStore — ENiX - SMTP - Using Gmail servers using App password — ENQuick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411 — ENProgram example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3. — ENProgram example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3. — ENProgram example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3. — ENQuick start guide - Connect X2 HMI with Nexto PLC, SUEN00414 — ENQuick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series, SUEN00402 — ENQuick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406 — ENQuick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405 — ENQuick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403 — ENBattery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs — ENMTBF Summary X2 base v2 — ENX2 export control and dual use — ENX2 Letter of Volatility — ENEnvironmental report X2 base v2 — ENGuidelines for TxA and TxB migration to X2. — ENGuidelines for TxA and TxB migration to X2. — .pptxCE certificate x2 base 15 v2 HP — ENCE Manufacturer declaration X2 base v2 — ENDoC battery X2 base (V2) — ENDoC ECCN for X2 series HMI — ENEnvironmental Impact Report X2 pro, X2 marine, X2 control, X2 motion — ENFCC certificate x2 base 15 v2 HP — ENKCC certificate X2 base 15 v2 HP — ENManufacturer declaration: X2 base v2 UKCA Declaration of Conformity — ENRoHS and REACH Declaration of Conformity — ENSDoC Green Passport — EN3D drawing X2 base 15 v2 HP — EN3D drawing X2 base 15 v2 HP — .stepCable CAB113: Cable for ModBus RS485 between X2 panel and BFI — ENInstallation manuals X2 base 15 v2 HP, MAEN333 — ENiX Developer Reference Manual, MAEN355 rev. B (current version) — ENX2 base / pro / extreme / marine / control - Configuration and Image manual , MAEN352 rev B — ENX2 base V2 Serial interface mapping — ENRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — ENRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — .exeRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — .zipSqlProxy - Connects iX Panels transparently to SQL Server (161202C) — ENSqlProxy - Connects iX Panels transparently to SQL Server (190115) — ENSqlProxy - Connects iX Panels transparently to SQL Server (191016C) — .zipSqlProxy - Connects iX Panels transparently to SQL Server (170330) — ENX2 brochure (English), BREN631 — ENX2 brochure (Spanish)​ — ESX2 brochure 2019 (French) — FRX2 series (German) — DEX2 base v2 (HP) 1.0.2 b280 — .cfgX2 base v2 (HP) 1.0.2 b280 — .exeX2 base v2 (HP) 1.0.2 b280 (LastMinuteNotes B280) — ENX2 base v2 (HP) 1.0.2 b280 (ReleaseNotes B280) — ENX2 base V2 1.1 (Current version) (LastMinuteNotes B1015) — ENX2 base V2 1.1 (Current version) (ReleaseNotes B1015) — ENX2 base V2 1.1 (Current version) ( — .exe
EXPLORE THE PORTFOLIO

Related products

WhatsApp
GET IN TOUCH

Let us call you.

Leave your number and let’s discuss what you need.

Your privacy choices

We use technologies needed to operate the website securely. Analytics and advertising tracking are disabled by default.

No analytics service is currently configured.